MachinistCharts

M27 bolt torque

Tighten an M27 × 3 class 8.8 bolt to 1,116 N·m (823 ft-lb) with dry threads, or 837 N·m when lubricated. Class 10.9 takes 1,544 N·m and class 12.9 takes 1,805 N·m.

Calculated from ISO 898-1 and ISO 724. Updated .

Class 8.8, dry threads
1,116N·m
823 ft-lb  or  9,881 in-lb
Class
Threads
Unit
Torque dialBands mark each grade at dry torque

M27 torque by property class

Tap a row to show it on the dial. The unit switch above changes every value on this page.

M27 bolt torque by property class, dry and lubricated
Property classDry torqueLubricatedClamp loadProof loadProof stress

Clamp load is 75 % of proof load. Dry: K = 0.20. Lubricated: K = 0.15.

M27 at a glance

Wrench, hex key, drill and clearance sizes for the same bolt, so you can set up the job from one page.

Ø27S 41P 3
M27 × 3 hex bolt, ISO 4017Proportions to scale
Thread
M27 × 3 coarse
Stress area As
459.4 mm²
Wrench / socket
41 mm
Hex key, socket cap
19 mm ISO 4762
Tap drill
24 mm
25 mm for M27 × 2
Proof load, 8.8
275.6 kN
Clearance hole, ISO 273
28 close   30 normal   32 loose mm

Before you tighten

Lubricant changes the number

Oil, moly paste or anti-seize lowers the nut factor K, so the same torque produces far more clamp load. Use the lubricated value whenever the threads are oiled, or the bolt can yield.

Tighten in a star pattern

On flanges and covers, bring every bolt to about 30 %, then 70 %, then full torque, crossing the pattern each pass. Finish with one round at full torque in sequence.

Give the thread enough grip

Engage at least one diameter of thread in steel, about 1.5 diameters in cast iron and 2 diameters in aluminium, or the internal thread strips before the bolt reaches its clamp load.

These are general starting values for steel bolts in steel nuts or tapped steel. When the equipment, gasket or fastener maker publishes a torque, use theirs. Never reuse torque-to-yield bolts.

How the number is worked out

The M27 class 8.8 figure, step by step. Every size on this site is calculated the same way.

T = K × F × d
K
0.20, nut factor for dry plain steel
F
206.7 kN, 75 % of the 275.6 kN proof load
d
27 mm, nominal diameter
T = 0.20 × 206,733 N × 0.03 m = 1116.4 N·m

Where the inputs come from

Proof stress is taken from ISO 898-1: 600 MPa for class 8.8 at this diameter, 830 MPa for 10.9 and 970 MPa for 12.9. Multiply by the tensile stress area of 459.4 mm² to get the proof load.

The stress area comes from As = π/4 × (d − 0.9382 p)². Target clamp load is 75 % of proof load, the usual figure for joints that will be taken apart again.

Lubricated values use K = 0.15. For other coatings or preload targets, use the torque calculator.

Other metric sizes

Common questions

What is the torque for an M27 8.8 bolt?

About 1,116 N·m (823 ft-lb) with dry threads and about 837 N·m lubricated, based on 75 % of proof load.

What is the torque for an M27 10.9 bolt?

About 1,544 N·m (1,139 ft-lb) dry and 1,158 N·m lubricated.

What is the torque for an M27 12.9 bolt?

About 1,805 N·m (1,331 ft-lb) dry and 1,354 N·m lubricated.

What size wrench fits an M27 bolt?

41 mm for ISO hex bolts. An M27 socket head cap screw takes a 19 mm hex key.

What drill size do I need to tap M27?

Use a 24 mm drill for M27 × 3 coarse thread.